{"id":96263,"date":"2024-02-07T10:40:51","date_gmt":"2024-02-07T09:40:51","guid":{"rendered":"https:\/\/lightweb.dev\/s\/key2compliance\/?p=96263"},"modified":"2024-02-08T12:53:21","modified_gmt":"2024-02-08T11:53:21","slug":"iec-60601-meeting-the-electrical-safety-standards-of-medical-devices","status":"publish","type":"post","link":"https:\/\/lightweb.dev\/s\/key2compliance\/blog\/iec-60601-meeting-the-electrical-safety-standards-of-medical-devices\/","title":{"rendered":"IEC 60601 \u2013 Meeting the Electrical Safety Standards of Medical Devices"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"96263\" class=\"elementor elementor-96263\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d85b9b3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d85b9b3\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9ac3c14\" data-id=\"9ac3c14\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-bf3e01a elementor-widget elementor-widget-text-editor\" data-id=\"bf3e01a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><span class=\"TextRun SCXW252973702 BCX8\" lang=\"EN-GB\" xml:lang=\"EN-GB\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW252973702 BCX8\">Read and learn more about IEC 60601 and IEC 61010, and the factors you should consider <\/span><span class=\"NormalTextRun SCXW252973702 BCX8\">when<\/span><span class=\"NormalTextRun SCXW252973702 BCX8\"> develop<\/span><span class=\"NormalTextRun SCXW252973702 BCX8\">ing<\/span><span class=\"NormalTextRun SCXW252973702 BCX8\"> a regulatory-compliant medical device.<\/span><\/span><span class=\"EOP SCXW252973702 BCX8\" data-ccp-props=\"{&quot;335557856&quot;:16777215,&quot;335559738&quot;:240,&quot;335559739&quot;:240}\">\u00a0<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0673b7 elementor-widget elementor-widget-text-editor\" data-id=\"e0673b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Electrical devices are part of our everyday lives, and they are undoubtedly cornerstones of our society and technology \u2013 this applies to the industries of life sciences and medical technology as well. However, it\u2019s important to understand that these devices could also pose some risks, ranging from electrical shock, fire, and interference with other devices.<\/p><p><span style=\"color: var( --e-global-color-text );\">Due to their diverse and complex nature, medical devices can however be potentially prone to errors. In fact, a <\/span><a style=\"background-color: #ffffff;\" href=\"https:\/\/bmjopenquality.bmj.com\/content\/11\/2\/e001849\" target=\"_blank\" rel=\"noopener\"><b>report<\/b><\/a><span style=\"color: var( --e-global-color-text );\"><b> <\/b>found that from 2008 to 2017, 1.7 million injuries could probably have been related to medical devices. This further highlights the importance of meeting the regulatory standards for medical devices.<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">Fortunately, the regulatory world of medical electrical devices has been refined over several decades of robust standards as well as the newest, most advanced equipment. However, entering this segment without any prior experience can be a daunting task.<\/span><\/p><p><span style=\"color: var( --e-global-color-primary ); font-size: 26px;\">Understanding IEC 60601 and 61010: the two families of technical standards for medical devices<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">Generally, there are two main families of technical standards for medical electrical devices: <\/span><strong style=\"color: var( --e-global-color-text );\">IEC 60601<\/strong><span style=\"color: var( --e-global-color-text );\"> and <\/span><strong style=\"color: var( --e-global-color-text );\">IEC 61010<\/strong><span style=\"color: var( --e-global-color-text );\">.<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">The <\/span><strong style=\"color: var( --e-global-color-text );\">IEC 60601<\/strong><span style=\"color: var( --e-global-color-text );\"> family of standards is most commonly associated with medical electrical devices. This includes the safety and essential performance requirements for devices that have an applied part in contact with the patient; facilitate energy transfer to or from the patient; and devices that detect energy transfer to or from the patient.<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">Some of the devices that fall under this family of technical standards are ventilators, operating tables, x-ray machines, and hearing aids.<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">The <\/span><b style=\"color: var( --e-global-color-text );\">IEC 61010<\/b><span style=\"color: var( --e-global-color-text );\"> family of technical standards is for laboratory and measurement equipment, and applies to medical equipment outside the scope of IEC 60601. This includes laboratory equipment used for measurement and analysis \u2013 most commonly associated with in vitro medical devices, but also for industrial control devices. To help make the distinction between the two main families of technical standards, IEC 61010 is generally for medical devices that do not make any physical contact with the patients.<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">The two series of technical standards follow a similar structure: a general standard with a subset of standards applied, based on device type, environment, and application. For IEC 60601, this also includes a standard on electrostatic discharge (ESD).<\/span><\/p><p><span style=\"color: var( --e-global-color-primary ); font-size: 26px;\">Important factors to consider in developing your medical device<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">Given the complex nature of medical devices, keeping mentioned factors in mind while developing your medical device can assist you in the long run.<\/span><\/p><p><strong style=\"color: var( --e-global-color-text );\"><span style=\"font-size: 120%;\">1. Consider the standards early on<\/span><\/strong><\/p><p><span style=\"color: var( --e-global-color-text );\">Medical electrical equipment and devices are subject to more rigid and stringent requirements due to the nature of the field \u2013 a failure or an incident directly related to medical devices, will have major consequences. Therefore, it\u2019s important to as early as possible, identify the main standard family, as well as the applicable subset of standards for the devices in question, to minimise and avoid issues during development.<\/span><\/p><p><strong style=\"color: var( --e-global-color-text );\"><span style=\"font-size: 120%;\">2. Risk management is crucial<\/span><\/strong><\/p><p><span style=\"color: var( --e-global-color-text );\">Risk management according to IEC 14971 is highly integrated in the IEC 60601 standard family. There are parts that provide requirements for the risk management file (RMF), as well as parts that require input from the RMF, e.g. risk based worst case scenarios to test. The same applies to usability according to IEC 62366.<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">While the IEC 61010 standard family is less integrated with the risk management and usability, both risk management and usability are still part of the requirements of the standard.<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">The risk management and usability management should be performed in parallel with development according to both standard families.<\/span><\/p><p><strong style=\"color: var( --e-global-color-text );\"><span style=\"font-size: 120%;\">3. Identify the correct components for your medical device<\/span><\/strong><\/p><p><span style=\"color: var( --e-global-color-text );\">With the abundance of electronic devices available today, there are plenty of choices when it comes to components for your medical device. It\u2019s important to keep in mind that not all components suitable for everyday electronic and industrial devices, would be suitable for medical devices \u2013 this also applies to component ratings such as environment range, voltages, flammability classifications, and certification status.<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">Identifying exactly which components are crucial for the safety of your medical device is important, to ensure that the device will meet the certification for the intended market \u2013 something that will also help you prevent unexpected and avoidable issues during testing. It\u2019s worth noting that opting for non-certified components at a lower price, can result in severe issues later that would end up costing you more.<\/span><\/p><p><strong style=\"color: var( --e-global-color-text );\"><span style=\"font-size: 120%;\">4. Does your device have embedded software?<\/span><\/strong><\/p><p><span style=\"color: var( --e-global-color-text );\">If so, there\u2019s a chapter for programmable electrical medical systems (PEMS), which refers to the medical software standard IEC 62304. This may or may not be applicable based on whether the software is considered safety-critical or not. Since IEC 62304 is a process standard for software development, identification of applicable parts is important early on in order to be fully compliant.<\/span><\/p><p><span style=\"color: var( --e-global-color-primary ); font-size: 26px;\">Learn more about electrical safety standards of medical devices with Key2Compliance<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">Key2Compliance offers courses, conferences, and training tools that assist life sciences companies in meeting their goals. Besides this, we offer complete and optimised solutions for companies developing medical devices including diagnostics, fillers, and combination products.<\/span><\/p><p><span style=\"color: var( --e-global-color-text );\">If you\u2019re interested in learning more about the electrical safety of medical devices, please watch our <strong>free 20 minute webinar<\/strong> with an <\/span><span style=\"color: var( --e-global-color-text );\">introduction to IEC 60601.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-c591d59 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c591d59\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-814803d\" data-id=\"814803d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-27974fb elementor-widget elementor-widget-button\" data-id=\"27974fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/vimeo.com\/721098115\" target=\"_blank\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"far fa-play-circle\"><\/i>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Play webinar<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-90e8800\" data-id=\"90e8800\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ac29628 elementor-widget elementor-widget-button\" data-id=\"ac29628\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/lightweb.dev\/s\/key2compliance\/about-us\/#contact\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"far fa-arrow-right\"><\/i>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contact our experts<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Read and learn more about IEC 60601 and IEC 61010, and the factors you should consider when developing a regulatory-compliant medical device.\u00a0 Electrical devices are part of our everyday lives, and they are undoubtedly cornerstones of our society and technology \u2013 this applies to the industries of life sciences and medical technology as well. However, [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":96279,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"wds_primary_category":192,"footnotes":""},"categories":[192,21],"tags":[288,290,117],"blog-subject":[],"class_list":["post-96263","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-news","tag-electrical-safety","tag-iec-60601","tag-medical-device"],"acf":[],"_links":{"self":[{"href":"https:\/\/lightweb.dev\/s\/key2compliance\/wp-json\/wp\/v2\/posts\/96263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lightweb.dev\/s\/key2compliance\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lightweb.dev\/s\/key2compliance\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lightweb.dev\/s\/key2compliance\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/lightweb.dev\/s\/key2compliance\/wp-json\/wp\/v2\/comments?post=96263"}],"version-history":[{"count":0,"href":"https:\/\/lightweb.dev\/s\/key2compliance\/wp-json\/wp\/v2\/posts\/96263\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lightweb.dev\/s\/key2compliance\/wp-json\/wp\/v2\/media\/96279"}],"wp:attachment":[{"href":"https:\/\/lightweb.dev\/s\/key2compliance\/wp-json\/wp\/v2\/media?parent=96263"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lightweb.dev\/s\/key2compliance\/wp-json\/wp\/v2\/categories?post=96263"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lightweb.dev\/s\/key2compliance\/wp-json\/wp\/v2\/tags?post=96263"},{"taxonomy":"blog-subject","embeddable":true,"href":"https:\/\/lightweb.dev\/s\/key2compliance\/wp-json\/wp\/v2\/blog-subject?post=96263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}